logo

M2M

Nano OUT

  Nano OUT – switching devices by web

Nano out switching devices by web

Nano out switching devices by web

Miniature module enables switching devices via the Internet. Nano OUT has 1 relay output controlled by the LAN.

NANO OUT device is used to control a single electrical circuit using a relay.

Controling the state is carried out by web using the built-in website, network protocols or software.

Supported protocols

  •  HTTP (GET)
  •  SNMP
  •  MODBUS TCP
  •  TCP (available protocol)

nanoout1

 

Modules LanTick and Nano can cooperate  without a computer.

An example of a direct connection (M2M) between the module Nano IN and Nano OUT.

 

Activity:

After triggering the input in the Nano IN device the assiocated relay
in Nano OUTdevice will be triggered

 

M2M nano in nano out

Example configuration:

Moduł NANO IN

Moduł NANO OUT

Network -> IP Address: 192.168.111.15

Network -> IP Address: 192.168.111.16

Network -> IP Mask: 255.255.255.0

Network -> IP Mask: 255.255.255.0

Network -> Destination IP: 192.168.111.16

Administration -> Enable Destination Client

Network -> Destination PORT: 9761

Channel -> Dest:1

 

nano-out dimension

The dimensnion fo NANO OUT module in millimeters

 

LanTick PE-8-0

Lantick PE-8-0 alows to control of devices by web. The module has 8 relay outputs

Control of devices by web

Lantick PE-8-0 control of devices by web

Lantick PE-8-0 control of devices by web

Lantick PE-8-0 alows to control of devices by web. The module has 8 relay outputs

Normally visualization of outputs state is available to prepare on your own graphics. In addition, the module allows you to change the displayed graphic by activating the selected output.

Reading and changing the status of the outputs is possible by:

  • internet browser
  • dedicated program running under Windows XP or late
  • Linux OS command line
  • MODBUS TCP protocol
  • SNMP protocol
  • HTTP (GET) protocol
  • smartphone/tablet with Android
  • KNX-IP

The device has a 2-level authorization (Administrator and User).

The following is a view of the main screen where you can see the number of the relay, the assigned name, the changing state and the indicator showing the current state.

home

 

The device allows you to load the graphics on the web browser where are arranged controls used to read and change the state of the assigned output.

Lantick PE-8-0 control of devices by web

Example of relays configuration:

channel

Technnical data LanTick PE-8-0

Conffiguration waybuilt-in web server
Number of outputs8
Type of outputsrelay
supply voltage12-24VDC
InterfaceRJ45 (10BASE-T)
Supported protocolsHTTP, TCP, SNMP, MODBUS TCP,
Wymiary
Working temperature5 – 50 °C
Storage temperature-10 to 85 °C
Humidity5-95%

Go to the store

LanTick PE-4-4

Control of electrical devices by web

Control of electrical devices by web

Lantick PE-4-4 control of electrical devices by web

LanTick PE-4-4 alows to control of electrical devices by web. Module  possess 4 opto-isolated inputs and 4 relay outputs. Using the module relays can be controlled via LAN / WAN.

Normally visualization of outputs state is available to prepare on your own graphics. In addition, the module allows you to change the displayed graphic by activating the selected output.

Reading and changing the status of the inputs is possible by

  • internet browser
  • dedicated program running under Windows XP or late
  • Linux OS command line
  • MODBUS TCP protocol
  • SNMP protocol
  • HTTP (GET) protocol
  • KNX-IP protocol
  • smartphone/tablet with Android

The device has a 2-level authorization (Administrator and User).

The following is a view of the main screen where you can see the number of the relay, the assigned name, the changing state and the indicator showing the current state.

 

home-4-4

Technical Data LanTick PE-4-4

Configuration waybuilt-in web server
Number of inputs4
Type of inputsoptoinsulated
Number of outputs4
Type of outputsrelay
Supply voltage12-24VDC
InterfaceRJ45 (10BASE-T)
Supported protocolsHTTP, TCP, SNMP, MODBUS TCP,
Work temperature5 – 50 °C
Storage temperature-10 to 85 °C
Humidity5-95%

In the “Download” there  is available LanTick Data Logger application which enables monitoring, stored in a CSV format and send via e-mail inputs and outputs states

.

f1

Go to the store

LanTick PE-2-2

 

Control of electrical devices by web

Lantick PE-2-2 control of electrical devices by web

Lantick PE-2-2 control of electrical devices by web

Lantick PE-2-2 alows to  control of  electrical devices by web. The module has 2 relay outputs rated at 250V, it is controled by TCP / IP  protocol. The module also has 2 opto-isolated digital inputs that can operate in counter mode.

Management and configuration of the device can be done in folowing ways:

  • by built-in website
  • by  program run from a command line WINDOWS / LINUX OS
  • by MODBUS TCP protocol
  • by SNMP protocol
  • by smartphone or tablet with Android

The modules can be connected  in M2M mode.

Lantick pe-2-2 połączenie M2M przekaźnik internetowy sterowanie przez internet

Lantick – M2M connection

 

 

pe2-2-dimDimensions of the PE-2-2 in millimeters.

Go to the store

Lantick PE-0-8

 Check inputs status by web

 

Lantick PE-0-8 checki inputs status by web

Lantick PE-0-8 checki inputs status by web

Lantick PE-0-8 alows to check inputs status by web. The module has 8 inputs opto-isolated inputs which visualization can be presented on the website.

Normally visualization of inputs state is available to prepare on your own graphics. In addition, the module allows you to change the displayed graphic by activating the selected input.

Reading and changing the status of the inputs is possible by:

  • internet browser
  • dedicated program running under Windows XP or late
  • Linux OS command line
  • MODBUS TCP protocol
  • SNMP protocol
  • HTTP (GET) protocol
  • smartphone/tablet with Android

The device has a 2-level authorization (Administrator and User).

The following is a view of the main screen where you can see the current status of the input and the status of the counters assigned to each inputs.

home

Technical Data Lantick PE-0-8

Configuration waybuilt-in web server
Number of inputs8
Type of inputsoptoinsulated
Supply voltage12-24VDC
InterfaceRJ45 (10BASE-T)
Supported protocolsHTTP, TCP, SNMP, MODBUS TCP,
Working temperature5 – 50 °C
Storage temperature-10 to 85 °C
Humidity5-95%

In the “Download” there  is available LanTick Data Logger application which enables monitoring, stored in a CSV format and send via e-mail inputs states

.

Lantick PE-0-8 check inputs status by web

LanTick Data Logger

Go to the store